Version History and Compatibility

This page summarizes the major product changes that SANPO SPINE customers can verify from official firmware, release manifests, migration guides, and public repository records.

Currently Released Versions

Product generation

MCU platform

Current firmware

Application

V8

STM32G0B1RCT6 with an external HSE crystal

V83

V8 hardware; native passthrough interfaces and V6-compatible protocol mode

V6

STM32G0A series

V68

G0A hardware using the V6 protocol; not interchangeable with G473 firmware

V6

STM32G473

V67

V6 FDCAN upgrade; CAN FD, Classic CAN, and RS485

V4

STM32F407

V47

V4 standard and isolated versions; Classic CAN and RS485

A complete SPINE board contains two MCUs. During a normal upgrade, program and verify both MCUs separately. Send AT+VER through each management serial port and confirm that both chips report the expected version.

Main Differences Between the Three Generations

Capability

V8

V6

V4

Classic CAN

Supported

Supported

Supported

CAN FD

Supported

Added

Not supported

Linux SocketCAN

Classic CAN/CAN FD

Classic CAN/CAN FD

Classic CAN in V47

USB management-port protocol

Retains V6-compatible protocol mode

Unified ST/ET/SF/EF/RT framing

V4 framing

USB RS485

One independent USB serial port per channel for direct passthrough, with RT protocol mode retained

RT framing with selectable RAW channels

V4 protocol framing

SPI

Retains the V6 SPI protocol

Fixed-length SHORT/LONG transfers with CRC-8

V4 fixed layout

Native CAN passthrough

Linux gs_usb/SocketCAN; Windows 10/11 system WinUSB with SANPO CANgaroo support

Linux gs_usb

Linux gs_usb

Offline batch commands

Retained

Retained and extended

Supported

Customer firmware development

STM32G0B1 framework and direct-development examples

Framework selected for the specific V6 MCU

STM32F407 framework

Version Evolution

V8: Native Passthrough Alongside Protocol Mode

V8 uses the STM32G0B1RCT6 and organizes its interfaces around two paths: direct access and compatibility with existing systems.

  • CAN/CAN FD appears directly as SocketCAN interfaces on Linux. Windows 10/11 uses the system WinUSB driver and can transmit and receive through SANPO CANgaroo or a user application.

  • The four RS485 channels appear as independent USB serial ports. Raw bytes pass through directly, without first selecting a SANPO Channel.

  • The management port and SPI retain the V6 ST/ET/SF/EF/RT frames, so SANPO Studio, CyberGear, GM8010, communication configuration, and offline batch tasks remain available.

  • Native passthrough mode or protocol mode can be selected according to the host application, real-time requirements, and compatibility needs.

Each MCU enumerates one dual-channel gs_usb device, one SANPO Studio Management Port, and two SANPO USB2RS485 Port interfaces. A complete dual-MCU board provides four CAN/CAN FD channels, two management ports, and four independent RS485 passthrough serial ports.

Recorded V8 production firmware releases:

Firmware

Major changes

V83

Retains all V82 functions while adding complete FDCAN error-state reporting and dual-path Bus-Off recovery; older drivers use automatic firmware recovery, while drivers supporting the extended protocol can use restart-ms or manual restart

V82

Completes the official release package, customer extension framework, CAN/CAN FD/RS485 examples, and J8108-R8 FDCAN test guide; reapplying identical FDCAN parameters restores the live configuration without an unnecessary Flash write

V81

First public V8 firmware; released the dual-MCU STM32G0B1 platform, dual-channel gs_usb, management port, and independent RS485 USB serial ports

V83 error handling uses standard Linux CAN error frames and does not introduce a proprietary SANPO error format. Only Bus-Off triggers controller recovery. Error Warning and Error Passive report status without incorrectly restarting the channel. CAN-A and CAN-B recover independently and do not actively restart the other CAN channel or RS485.

V6: CAN FD and a Unified Protocol

V6 adds CAN FD while retaining Classic CAN and RS485, and unifies communication framing and parameter configuration.

  • USB Classic CAN continues to use ST/ET, while CAN FD adds SF/EF.

  • USB RS485 normal mode uses the unified RT + Channel + Len + Data + CRLF frame.

  • SPI provides two fixed transfer lengths: 23-byte SHORT and 73-byte LONG, with CRC-8.

  • CAN/CAN FD, RS485, and SPI parameters are explicitly configured and stored through AT commands.

  • Linux SocketCAN supports both Classic CAN and CAN FD.

Later V6 firmware is maintained separately for each MCU platform:

  • G0A V68: Retains the V6 protocol and has completed high-frequency stress testing for USB RAW, USB RT, and SPI-to-RS485 operation. It is dedicated to G0A hardware and cannot be used with STM32G473 or V8 G0B1.

  • STM32G473 V67: Adds standard SocketCAN error frames, Error Warning, Error Passive, TEC/REC, and Bus-Off handling. Older gs_usb drivers continue to use 100 ms firmware-managed recovery. Drivers supporting the extended recovery protocol can control recovery through restart-ms or manual restart. Recovery discards stale control frames accumulated during Bus-Off so expired commands are not replayed afterward.

When migrating from V4 to V6, a USB Classic CAN application normally only needs to reconfirm its port and Channel. RS485 framing, SPI layout, CAN FD configuration, and communication-parameter setup must be adapted to the V6 documentation. See the V4 to V6 Migration Guide for details.

V4: Classic CAN and RS485 Foundation

V4 established the basic SPINE capabilities for USB, SPI, Classic CAN, RS485, communication-parameter configuration, and offline batch commands. V42 (V4.2) and later firmware support offline batch execution.

V47 is the final V4 release. Its main customer-visible state includes:

  • completed regression coverage for USB CDC, gs_usb/SocketCAN, SPI, Classic CAN, and RS485;

  • corrected Channel information in SPI-to-RS485 response frames;

  • customer extension projects for STM32CubeIDE and Keil;

  • AT+VER reports V47.